Detailed Product Description


SV-5Q automobile  exhaust emission Analyzer, in accordance with non-light-disguising infrared absorption method.The main technical parameters

1. Environmental temperature

Temperature-5-40  humidity: 95%  Air pressure:70.0-106kPa    Power:  AC  220V±10%;50Hz±1Hz

2.Measuremnt scopeHC:   0-1000010-6ppmvol CO:  0-10.0      10-2(%)vol

CO2:  0-20.0     10-2  (%)  volO2 0-25.0     10-2(%)volrotate speed0-10000rpm

NO:   0-5000      10-6ppmvoloil temperature0-120

3.Sampling methodtail gas: sampling directly .The length of sampling tube: 5m,the length of probe:900mm.

Oil temperatureinserting the head of thermo  scope into the staff gauge of engine lubricant, the length of which is the same as that of oil staff gauge; blocking with rubber plug to plug up engine oil from ejecting: length of lead: 5m.

Rated rpm Non-contact measurement method. Less than 20cm to the petrol high-voltage flexible cord, measuring petrol rotate speed.

4.preheat time10mins

5.resolutionCO 0.01%volHC: 1ppmvolnormal hexane equivalent CO2: 0.01%volO2: 0.01%vol

NO:  1ppmvol  rate speed 1rpm   oil temperature 0.1

6.indicated errorCO±0.06% vol or±5% relative error.   HC: ±12ppm vol or ±5% relative error

CO2: ±0.5% vol or ±5% relative error  O2: 0.1% vol or±5% relative error

NO±25ppm vol or±5% relative error   rate speed     ±10rpm(0-10000rpm) ±1% measured value  (>10000rpm)

7.Stabilityafter preheating, zero excursion and measurement distance excursion in 4 hours should not be over the allowance value of sample value error

8.Repetitiveness: ≤1/2 of absolute of the allowed sample value error

9.Output signal: Number volume: RS232 serial massage   exit.

图片

emission analyzer

Send your message to this supplier
« Prev Product 1 2 3 4 5 6 7 ... Next Product »

Other Products from this Supplier

Company Info

Tianjin Shengwei Development of Science Co., Ltd.
[China]
[Verified Member]

Business Type:Manufacturer

City: Tianjin
Province/State: Tianjin
Country/Region : China

View Contact Details

Email this page Bookmark this page Print this Page